Boost Your IT System’s Reliability with Effective Server Rack Cooling

Server Rack Cooling Fans

Introduction

In today’s fast-paced digital world, businesses rely heavily on their IT infrastructure to keep operations running smoothly. At the heart of this infrastructure are servers housed within server cabinets or server racks, which store and process critical data and applications. To ensure high performance and longevity of your network equipment and servers, it’s crucial to implement effective server rack cooling solutions. Poor cooling can lead to overheating, which directly impacts the performance of your systems, particularly in high-demand environments like data centres.
In this article, we’ll explore the importance of server rack cooling, popular cooling methods, best practices, and how to leverage cooling fans for efficient heat dissipation.

What is Server Rack Cooling and Why is It Essential?

Server rack cooling is the visible and invisible activities associated with and responsible for removing or controlling the heat generated within the server rack or cabinet that houses IT equipment. A server generates a lot of heat energy when operated and if this is not well managed, it could lead to overheating or degradation in performance or shutdown of the hardware. There’s an outright need to implement constant cooling facilities around server racks to eliminate thermal-related downtimes and improve performance efficiency through effective cooling solutions despite the pictures displaying the equipment in a safe range of inside the rack temperature.

How Server Rack Cooling Impacts System Performance and Longevity

Being overly hot can harm server elements to the point that they are forced to reduce performance or turn off completely to escape destruction. As the report done in Uptime Institute shows that for each incremental 10°C (18°F) in temperature above the normal operational range of network devices, one could expect an electronic equipment failure rate that is doubled. Taking steps for good ventilation to achieve these cold temperatures will help to avoid such hardware redundancy in your system for very costly replacements and the hardware will serve you for a long time.

Popular Server Rack Cooling Solutions

There are various server rack cooling solutions available, each with its own advantages and considerations. Two primary categories of cooling systems are air cooling and liquid cooling. Let’s take a closer look at each:
Air Cooling Systems

Air Cooling Systems

Heat is removed from the server racks in the most accessible way, using air. The method is utilizing fans and vents to bring in cold air into the rack and bring out hot air with the hope of reducing the heat load from the active components within the equipment. The air cooling systems also come in two major heads which include:
Cooling at room level: This uses air conditioners or precision coolers to cool down the entire server room under vent boxes or air ducts. Cool air flows to the room, and hot air is removed via vents or ducts. Fan panels fitted on server racks such as those around the hot aisle ensure that hot air is discharging while cool air is circulating to the core for optimal functioning of the racks in the entire data center and creates a proper airflow arrangement.
Row Cooling Systems: This method involves placing cooling apparatus in the free spaces between or on the top of server racks for optimal cooling at certain areas. For example, in-row cooling systems or rack mount cooling fans can be used to bring cold air to the front of the rack and exhaust hot air from the rear. This provides the neatness of the cooling system while providing high efficiency in the cooling process and good temperature management minimizing the heat load on the whole system.
liquid cooled racks

Liquid Cooling Systems

Liquid cooling has also gained popularity in the recent past as a server rack cooling solution utilized for high density server usages. Liquid cooling involves the use of liquids such as water and other special fluids to draw heat from the server processors and chillers in the rack. Water and cooling tubes are better suited for cooling systems than air cooling as liquids are more efficient in heat dissipation due to high capacity.
A rackmount cooling unit working on liquid cooling technology might consist of heat exchangers and pumps in addition to being a cooling unit itself to move heated fluid throughout the cooling unit. These systems are very often equipped with temperatures and thermometers to ensure that the cooling system works properly. Within some data centre environments where this is the case, other horizontal liquid cooling solutions include immersion cooling tanks where non-conductive liquids are used to fully enclose high-performance servers to improve heat transfer and maintain the servers within optimum work conditions.
Cooling Method Advantages Common Equipment Used Best For
Air Cooling Systems – Widely available
– Lower upfront cost
– Fan panels
– Rack mount cooling fans
– Standard server racks
– Low to medium heat loads
Liquid Cooling Systems – Higher heat dissipation efficiency
– Ideal for high-density setups
– Heat exchangers
– Rack-mounted cooling units
– Pumps
– High-performance data centers
– High-density server deployments

Using Server Rack Cooling Fans to Optimize Heat Dissipation

Essential to avoiding overheating in the server rack is making use of server rack cooling fans. They operate as follows: cold air is concentrated within the enclosed rack; the bodies of the server are engulfed in cold air and installed; warm air is expelled outside the enclosure. In this part, we will introduce some of the cooling fans and how they work:

Different Types of Cooling Fans for Server Racks

Choosing the right type of fan for server rack cooling systems is important as this ensures both efficiency of cooling and optimal use of height. There are several fan types that are used in a server rack cooling system. Every type is unique in its effectiveness and space efficiency. Let us examine some of these fan types:
Axial Fans: This is the most prevalent type of fan that is found in the server rack. With these fans, the direction of air movement is along the tilt of the fan blade. Cool ambient air is drawn from the front of the rack and hot air is released at the back. Equipment using cooling fan systems with axial strategy are recommended for normal air penetration where free vertical heights are abundant.
Centrifugal Fans: A Centrifugal fan is one that takes air in from the side and discharges it at right angles to the intake via a rapidly revolving impeller. Such fans are appropriate for server racks, which have no vertical space, in that they can deliver high static pressure to counter the splayed server buildings or blocked air flow passages.
Radial Fans: In centrifugal radia fan (also can be referred to as a blower) exhaust, air is drawn in from the sides, flows out horizontally or exhaust radially. They are smaller in size and can be fitted on the back of server rack doors, thereby making them good options for racks with limited vertical space. The radial fans are particularly effective in pulling hot air from the component of servers and discharging it within the rack.
Cross-Flow Fans: Cross flow fans or tangential fans are different from other fans as they have been designed to deliver wide but uniform air flow throughout the length of the fan. These fans will be used to ensure that ambient air is uniformly supplied to different servers working in a rack which needs cooling. Depending on rack configuration and cooling needs crossflow fans can be oriented multi-directionally or placed in either only vertical or horizontal position.
Roof-mounted fans: These fans are fitted on the upper side of the server rack and are responsible for evacuation of hot air from within the rack. These fans create a negative pressure within the rack by sucking up cooler air at the bottom and sides.
While planning the cooling system for server racks fan selection, the following parameters need to be taken into various factors – horizontal and vertical dimensions, the volume of air to be moved, static pressure, and the cooling that each device is required to have. There is still a fan noise to be factored in, fan power consumption as well as fan mounting on the rack unit concerns.

How Cooling Fans Work: Air Intake, Circulation, and Exhaust

Rack mount cooling fans work by establishing a predetermined airflow pattern throughout the server rack by having a centralized cooling regions in the rack so that cool air is always delivered where it is most needed. Usually cool air is let in to the clamped rack enclosure either through the front portion or lower part which air passes through server parts, in turn absorbing heat from them. The very air circulated by the cooling fans is drawn or pumped out with distance by the servers and each piece of network equipment which – owing to heat dispersions , lightens the heat load inside the rack.
Exhaust fans or vents are usually employed to rid a system of its heat by blowing out the heated air released from the rear or upper portion of the rack. This promotes the removal of heated air from the system. This continuous movement of air avoids the formation of warm air pockets in the closed rack, and helps preserve a more constant environment necessary for the high operational efficiency and durability of the server and other IT equipment.
server fans

Best Practices for Effective Server Rack Cooling

When it comes to cooling server racks, there are best practices that one should observe in order to improve cooling efficiency and limit unknown risks. Here are tips to bear in mind:

Proper Airflow Management

Proper management of airflow is crucial in the cooling of server rack enclosures. This includes making sure that cool air is supplied to server components while hot air is removed from the server. Some best practices include:
Sealing unused rack spaces: Use blanking panels on the unused spaces of the rack so that hot air is confined, making airflow efficient.
Cable management: Excessive cable use should be avoided and well routed cables should be used so that there are open passages in the rack for air movement. .
Hot aisle/cold aisle layout: In this technique server racks are arranged in a manner where there are hot and cold aisles between different racks. Cold aisles are those with fronts of the racks facing cold air and the back of these racks facing the hot air while in the hot aisle.There is therefore a good means of separating the hot and chin streams within the moderate space, thus enhancing the efficacy of cooling .

Regular Maintenance

Proper performance of cooling systems in the server racks is achievable once the systems are maintained on a constant basis. Some of the maintenance measures include:
Cleaning air filters: Air filters found in cooling fans mounted on the cooling units and server racks should be cleaned or replaced at regular intervals because dust deposits impede air flow.
Inspection of Fans: Check the cooling fans for wear, damage or performance degradation. Repair or replace them as needed to avoid airflow restrictions.
Electronic equipment temperature/humidity control: Continuous measurements of temperature and humidity at appliance storage locations and within the data centre. Remain within the allowable limits in order to maximize the performance of the equipment inside.

Monitoring and Alerting

Deploying monitoring and communication systems is crucial for active management of cooling in server rack systems. These systems help.
Measuring temperature and humidity: Sensors can be employed for both temperature and humidity monitoring in the computer room and within the enclosure of the rack.
Defining Alarms and thresholds: These alarm and threshold settings allow you to receive out of range temperature or out of range humidity alerts that will help you take appropriate measures in good time.
Pattern recognition: Patterns and trends in the data collected on temperature and humidity can be helpful in cooling management strategies to avert problems that would otherwise occur.

Conclusion

Effective server rack cooling is crucial for maintaining the reliability, performance, and longevity of your IT systems. By understanding the importance of cooling, exploring various rack cooling solutions, and implementing best practices, you can ensure that your network equipment and servers operate at optimal temperatures, reducing the risk of downtime and hardware failure. Regular maintenance, proper airflow management, and temperature monitoring should be integral parts of your cooling strategy, particularly for high performance environments like data centres. By doing so, you’ll be well-equipped to keep your IT systems running smoothly and reliably.
Need help optimizing your cooling systems? Contact us today for a free consultation or demo of our top-rated fan cooling solutions!

FAQs:

How can inefficient cooling impact the performance and lifespan of server equipment?

What are the consequences of an inefficient cooling system on server equipment performance and service?
Inefficient cooling can lead to a variety of issues with server equipment, these include:
Overheating: Servers without proper cooling can get dangerously hot, and their components will be forced to either throttle their performance or simply turn off to prevent damage. This can lead to, quite unnecessarily, performance reduction to the systems and possible hardware malfunction.
Reduced lifespan: Continuous exposure to high temperatures can accelerate wear and tear among the server components, reducing their life span and increasing their chances of breakage.
Increased energy consumption: inefficient cooling systems will demand more energy to arrive at the required temperatures. This increases operational costs and leads to increased emissions.

How often should server rack cooling systems be maintained?

The repair intervals of server rack cooling systems will vary from solution to solution, environment to environment, and manufacturer to manufacturer. But as a rule of thumb:
Air filters should be cleaned or changed in a range of 1 to 3 months with the dirtiness of the working area playing a major role.
Cooling fans should be checked at 3 to 6 months intervals for any signs of wear and tear, physical damage or performance deterioration.
Temperature and humidity levels should be constantly calculated especially at regular intervals to make sure that it does not go beyond the required limits.
Hence, the recommendations made by the manufacturer should be followed including the maintenance plan suited for your particular server rack cooling system and environmental conditions. Routine maintenance eliminates the risk of some problems occurring and confirms that the systems are working optimally and any cooling systems.

Quick Quotation

Wonderful! Share this Case:

Related Articles

Discover the top 7 industrial cooling fan manufacturers on our blog.
Discover what is a brushless motor and delve into the world of BLDC technology.
Learn the best strategies for greenhouse cooling to maximize your yield.
Explore the differences between radial fan vs axial fan in our blog post.

Contact Info

+86 183 1666 5997

+86 020-3667 8158

+86 020-8337 7440

Our Address

Building 4, No.7 Lanhua Street, Dagang Industrial Zone, Baiyunhu Street, Baiyun District, Guangzhou, China.

ACDCFAN is a professional manufacturer of high-quality AC axial fans, AC radial fans, DC axial fans, DC radial fans, and EC axial fans.

© Copyright 2023. Guangzhou Guanxie Fan Manufacturing Co.,Ltd. All Rights Reserved